2015 A/L Physics Past Paper · Question 48 (English Medium)

Heating water through a row of rods

Water flows at a uniform rate through a tube of length LL, which is made of an insulating material. A large number of identical, uniform and insulated metal rods which are equally spaced as shown in the figure is connected between the tube and a large heat reservoir maintained at 100 ∘C100\ ^\circ\text{C} to transfer heat from the reservoir to the water in the tube.

If the inlet temperature of water is equal to the room temperature, which of the following graphs best represents the variation of the rate of flow of heat (R)(R) through the rods and temperature (θ)(\theta) of water along the length (x)(x) of the tube at the steady state?

  1. (1) Graph (1)
  2. (2) Graph (2)
  3. (3) Graph (3)
  4. (4) Graph (4)
  5. (5) Graph (5)
Answer and explanation

Answer: (5) Graph (5)

What the question asks

This question is about water flowing steadily through an insulated tube. Many identical metal rods join the tube to a large tank kept at 100 ∘C100\ ^\circ\text{C}, so heat flows down each rod into the water.

What we must find: how the heat flow RR through the rods and the water temperature θ\theta change along the tube.

How we find it: the heat through a rod depends on the temperature difference across it. The water warms because of that heat. Follow the two together along the tube.

What each letter means:

xx (m\text{m}): the distance along the tube from the inlet. LL: the length of the tube.

θ\theta (∘C^\circ\text{C}): the water temperature at xx. It starts at room temperature.

RR (W\text{W}): the rate of heat flow through the rod at xx.

KK, AA, ll: the conductivity, cross-section and length of a rod, the same for every rod.

Relevant theory

It has been shown experimentally when the rod is lagged, that the rate of flow of heat ΔQ/∆t in the steady state, is proportional to, (1) The cross sectional area of the rod (A) (2) The temperature gradient along the rod

What is happening: every rod has 100 ∘C100\ ^\circ\text{C} at its top and the water temperature θ\theta at its bottom. So the heat through it is

R=KAl(100−θ)R=\dfrac{KA}{l}(100-\theta)

Near the inlet the water is cold, the difference is big, and a lot of heat flows. That heat warms the water. Further on the water is warmer, the difference is smaller, and less heat flows.

For example, I walk past a row of identical heaters on a cold night, carrying a cold cup of tea.

At the first heater my cup warms up fast. By the time it is already warm, each heater adds less.

So the tea warms quickly at first and then more and more slowly.

Required equations

R=KAl(100−θ)R=\dfrac{KA}{l}(100-\theta)

dθdx∝R\dfrac{d\theta}{dx}\propto R

Reasoning and calculation

The graph has xx along the bottom and both θ\theta and RR up the side. At x=0x=0, θ\theta is room temperature and RR has its biggest value.

Split the tube into short pieces, one rod each. In each piece the water gains the heat RR of that rod.

The water flows at a steady rate, so each piece warms it by an amount that goes with RR:

dθdx∝R\dfrac{d\theta}{dx}\propto R

R∝100−θR\propto100-\theta

So θ\theta rises, but more and more slowly. RR falls, also more and more slowly.

Check a limit: if the water came in at 100 ∘C100\ ^\circ\text{C}, then 100−θ=0100-\theta=0, so R=0R=0 everywhere and θ\theta would stay flat. Colder water gives a bigger RR at the start.

Because RR goes with 100−θ100-\theta, the RR curve is a mirror image of the θ\theta curve: one bends up and flattens, the other bends down and flattens.

So the graph: θ\theta rises and flattens, RR falls and flattens, both curved, like mirror images.

Reading the options

Pick the graph where both lines curve and flatten, θ\theta up and RR down.

(5) θ\theta curves up and flattens, RR curves down and flattens. This is what we found.

Why the other options fail

(1) draws both as straight lines. But RR falls as the water warms, so the water warms more slowly further on: θ\theta must bend over.

(2) has RR rising. Warmer water is closer to 100 ∘C100\ ^\circ\text{C}, so less heat flows through the rods, not more.

(3) keeps RR constant. That would need the water to stay at one temperature, but the graph shows it warming.

(4) bends θ\theta but keeps RR straight. RR goes with 100−θ100-\theta, so it must bend in the same way, as a mirror image of θ\theta.

Conclusion

R∝100−θR\propto100-\theta and the water warms by RR, so θ\theta rises and levels off while RR falls and levels off. The answer is (5).

When the heat flow depends on the temperature it is changing, both curves bend and level off. Nothing here stays straight.

Exam tip

தமிழ் · සිංහල