2016 A/L Physics Past Paper · Question 44 (English Medium)

Keeping the dew point when three rooms mix

Absolute humidities of air inside three closed rooms AA, BB and CC of volumes VAV_A, VBV_B and VCV_C at atmospheric pressure are SAS_A, SBS_B and SCS_C respectively. [See figure (a)]. The dew point of air in room AA is T0T_0. When the doors are opened as shown in figure (b) and the air in three rooms are allowed to mix, the common dew point of the three rooms will remain at T0T_0 if

  1. (1) SA=VBSB+VCSCVB+VCS_A=\dfrac{V_BS_B+V_CS_C}{V_B+V_C}
  2. (2) SA=SB+SC2S_A=\dfrac{S_B+S_C}{2}
  3. (3) VASA=VBSB+VCSCV_AS_A=V_BS_B+V_CS_C
  4. (4) SAVA=SBVB+SCVC\dfrac{S_A}{V_A}=\dfrac{S_B}{V_B}+\dfrac{S_C}{V_C}
  5. (5) SA=SBSCS_A=\sqrt{S_BS_C}
Answer and explanation

Answer: (1) SA=VBSB+VCSCVB+VCS_A=\dfrac{V_BS_B+V_CS_C}{V_B+V_C}

What the question asks

This question is about three closed rooms of air. Each room has its own amount of water vapour in every cubic metre, its absolute humidity.

Then the doors open and the air of the three rooms mixes into one big space.

What we must find: the condition that keeps the dew point at T0T_0, the dew point room AA had before.

How we find it: the dew point depends only on the vapour in each unit volume. So the absolute humidity after mixing must still be SAS_A.

What each letter means:

VAV_A, VBV_B, VCV_C (m3\text{m}^3): the volumes of the rooms.

SAS_A, SBS_B, SCS_C (kg m−3\text{kg m}^{-3}): the absolute humidities, the vapour mass in each 1 m31\ \text{m}^3.

mm (kg\text{kg}): a mass of water vapour, m=S×Vm=S\times V.

T0T_0 (∘C^\circ\text{C}): the dew point of room AA.

We need the condition

Smix=SAS_{mix}=S_A

Relevant theory

Absolute humidity is defined as the mass of water vapour present in a unit volume of air in the environment.

The temperature at which the volume of air gets saturated for the first time with water vapour existing in it, is known as the dew point of that volume of air. The dew point of a given volume of air depends on vapour density in the volume and can be equal to less than or more than the room temperature.

What is happening: absolute humidity is vapour mass over volume, so the vapour mass in a room is

m=S×Vm=S\times V

When the doors open, no vapour is lost. The masses add, and the volumes add.

The dew point depends only on the vapour density. Room AA had dew point T0T_0 with density SAS_A. So the mixed air has dew point T0T_0 only if its density is again SAS_A.

For example, a cold drink bottle taken out of a fridge.

Dew forms on it when the air next to it cools down to its dew point. Whether you are in a small room or a big hall makes no difference. Only how much vapour each cubic metre of air holds decides when the bottle gets wet.

Required equations

m=VASA+VBSB+VCSCm=V_AS_A+V_BS_B+V_CS_C

Smix=VASA+VBSB+VCSCVA+VB+VCS_{mix}=\dfrac{V_AS_A+V_BS_B+V_CS_C}{V_A+V_B+V_C}

Smix=SAS_{mix}=S_A

Reasoning and calculation

SA(VA+VB+VC)S_A(V_A+V_B+V_C)

VASA+VBSB+VCSC=SA(VA+VB+VC)V_AS_A+V_BS_B+V_CS_C=S_A(V_A+V_B+V_C)

SA(VB+VC)S_A(V_B+V_C)

VBSB+VCSC=SA(VB+VC)V_BS_B+V_CS_C=S_A(V_B+V_C)

VBSB+VCSCVB+VC\dfrac{V_BS_B+V_CS_C}{V_B+V_C}

SA=VBSB+VCSCVB+VCS_A=\dfrac{V_BS_B+V_CS_C}{V_B+V_C}

The VASAV_AS_A on both sides cancels. What is left says that the air of BB and CC together must already have humidity SAS_A. This is option (1).

Units: m3×kg m−3m3=kg m−3\dfrac{\text{m}^3\times\text{kg m}^{-3}}{\text{m}^3}=\text{kg m}^{-3}, the unit of absolute humidity on both sides.

Reading the options

Now compare with the five options. Only (1) is the volume-weighted humidity of BB and CC.

(2) is a plain average. It is right only when VB=VCV_B=V_C. A bigger room holds more vapour, so each humidity must be weighted by its volume.

(3) says the vapour in AA equals the vapour in BB and CC together. That does not make the humidity after mixing equal to SAS_A.

(4) divides humidity by volume, which is not a mass of vapour. Absolute humidity times volume gives the mass.

(5) is a geometric mean. Vapour masses add, they do not multiply.

Checks

Limit case: if BB and CC have the same humidity as AA, SB=SC=SAS_B=S_C=S_A, mixing changes nothing, and (1) gives SAS_A. If CC is a tiny room, VC→0V_C\to0, (1) gives SA=SBS_A=S_B, as it must.

(V∗SB+V∗SC)/(V+V)(V * SB + V * SC) / (V + V)

Conclusion

SA=VBSB+VCSCVB+VCS_A=\dfrac{V_BS_B+V_CS_C}{V_B+V_C}

The dew point stays T0T_0 only if the humidity after mixing is SAS_A: VASA+VBSB+VCSC=SA(VA+VB+VC)V_AS_A+V_BS_B+V_CS_C=S_A(V_A+V_B+V_C), so SA=VBSB+VCSCVB+VCS_A=\dfrac{V_BS_B+V_CS_C}{V_B+V_C}. The answer is (1).

Mixing air: add the vapour masses S×VS\times V, add the volumes, then divide. The dew point follows the absolute humidity.

Exam tip

தமிழ் · සිංහල