2017 A/L Physics Past Paper · Question 35 (English Medium)
Heat shared by three rods
Figure shows an insulated network of heat reservoirs , , , and of which , and are identical. The reservoir operating at supplies heat and maintains the four other reservoirs , , and at the temperatures shown. Heat is supplied by connecting the reservoirs with insulated heat conducting rods of same material and having identical areas of cross-section. Lengths of the rods are not drawn to the scale. If the length of the conducting rod between and is , the length of the conducting rod between and will be
Answer and explanation
Answer: (2)
What the question asks
This question is about heat travelling along metal rods. A very hot reservoir X sends heat to a middle reservoir B, and B passes the heat on to three cooler reservoirs C, D and E.
All the rods are of the same metal, with the same thickness, and they are wrapped so that no heat escapes from their sides. Only their lengths can differ.
What we must find: how long the rod between B and D must be, if the rod between X and B has length L.
How we find it: in the steady state keeps the same temperature, so the heat coming into each second equals the heat leaving it. Write the rate of heat flow for each rod and solve for the length.
What each letter means:
(): temperature. , , and , , are at .
(): length of the rod –. (): length of each rod from to , or .
(): thermal conductivity of the metal. (): area of cross-section of a rod.
(): rate of heat flow along a rod.
Relevant theory
In the steady state, the rate of flow of heat through any cross section like P or R should be the same because the flow of heat is axial.
The proportionality constant K here is known as the thermal conductivity of the material of the rod.
Therefore, K is the rate of flow of heat per unit cross sectional area and per unit temperature gradient.
What is happening: heat flows from hot to cold along each wrapped rod. The rate of heat flow along a rod is
All rods have the same and the same . So the rate depends only on the temperature drop and the length: a bigger drop sends more heat, a longer rod sends less.
stays at , so in the steady state the heat arriving at each second all leaves again through the three side rods.
, and are identical and all at , so each one takes the same share: one third of the heat that reaches . Equal shares with equal drops of mean the three side rods have the same length .
For example, two metal spoons standing in the same cup of hot tea, one short and one long.
Touch the tops after a minute. The short spoon is already warm, the long one is still cool.
Heat has the same temperature drop to cover in both, but along the long spoon it flows more slowly. Doubling the length halves the rate of heat flow.
Required equations
Reasoning and calculation
The heat into through rod –, with a drop of :
The heat out of through three side rods, each with a drop of :
In the steady state these are equal. and cancel:
Reading the options
is option (2).
Each side rod carries a third of the heat with half the temperature drop, so it is times as long as rod –.
This turns the ratio upside down and also forgets that feeds three rods. The rate of heat flow goes as , so a longer rod carries less heat, not more. With all three rods counted, .
This assumes all rods have the same length because they are of the same material. But the temperature drop on rod – is and on each side rod only , and shares its heat between three rods. Equal lengths would not keep at .
This counts the three rods but puts the length on the wrong side. A rod carries heat at a rate proportional to , so the length divides. Then gives , not .
This balances rod – against one side rod only. But sends heat into three identical reservoirs , and , so each side rod carries only a third of the heat. Each side rod must be three times longer than , which is .
Checks
A second way, by shares: rod – has a drop of over . A side rod carries one third of that heat with a drop of .
Limit check: if fed only one reservoir, the same heat would go through one rod and gives . Sharing among three makes each side rod three times longer, .
Units check: each side of the balance is a rate of heat flow.
:
After and cancel, both sides are in , so comes out in metres, like . A length, as it should be.
Conclusion
In the steady state the heat into equals the heat out: , so . The answer is (2).
For a junction held at a steady temperature, heat in per second equals heat out per second. Each rod carries : the length always divides.
Exam tip