2026 A/L Physics Past Paper · Question 16 (English Medium)

Longer objectives in a microscope and a telescope

A compound microscope and an astronomical telescope are in normal adjustment positions. If the focal length of both objective lenses is increased, what will happen to the magnifying power of the microscope and the telescope, respectively?

  1. (1) Increases, decreases
  2. (2) Decreases, increases
  3. (3) Remains the same, increases
  4. (4) Increases, increases
  5. (5) Decreases, decreases
Answer and explanation

Answer: (2) Decreases, increases

What the question asks

This question is about two instruments that both use an objective lens and an eyepiece, but for opposite jobs.

A microscope looks at a tiny thing very close to it. Its objective makes a large real image of it, which the eyepiece then enlarges again.

A telescope looks at something very far away. Its objective forms the image near its focus, and the eyepiece makes that image look big.

What we must find: what a longer objective focal length does to the magnifying power of each.

How we find it: write each magnifying power with fAf_A in it, then see which way it moves when fAf_A grows.

What each letter means:

fAf_A (cm\text{cm}): the focal length of the objective. fBf_B (cm\text{cm}): the focal length of the eyepiece.

uu, vv (cm\text{cm}): object and image distances. v1v_1: the image distance of the microscope objective.

DD (cm\text{cm}): the near point distance, 25 cm25\ \text{cm}.

MM, mm (no unit): the magnifying powers of the microscope and the telescope.

Relevant theory

The lens closer to the object and known as the "objective" is a converging lens of very short focal length.

∴ 1/v − 1/u = 1/f is the lens formula.

Also linear magnification (m) = height of image / Height of object = OP/IP = |v/u|

Angular magnification , (m) = α/β = tan α / tan β = (h/f_B)/(h/f_A) = |f_A/f_B|

What is happening in the microscope: the objective forms a real image v1v_1 away, and the tube keeps v1v_1 about the same. The lens formula gives the magnification of the objective:

v1u1=v1fA−1\dfrac{v_1}{u_1}=\dfrac{v_1}{f_A}-1

The eyepiece gives 1+DfB1+\dfrac{D}{f_B}, and the two multiply:

M=(1+DfB)(v1fA−1)M=\left(1+\dfrac{D}{f_B}\right)\left(\dfrac{v_1}{f_A}-1\right)

What is happening in the telescope: the power is simply m=fAfBm=\dfrac{f_A}{f_B}.

For example, a nature photographer with two lenses.

To fill the picture with an eagle on a far tree, the photographer fits a long lens. The longer its focal length, the bigger the far eagle looks.

To fill the picture with the leg of an ant, the photographer needs a short close-up lens held right next to the ant. A long lens would only make the ant smaller.

Applying it to this question

v1u1=v1fA−1\dfrac{v_1}{u_1}=\dfrac{v_1}{f_A}-1

M=(1+DfB)(v1fA−1)M=\left(1+\dfrac{D}{f_B}\right)\left(\dfrac{v_1}{f_A}-1\right)

m=fAfBm=\dfrac{f_A}{f_B}

Reasoning and calculation

What is changed: fAf_A grows in both instruments.

What stays the same: the eyepieces (fBf_B), the near point DD and the microscope tube (v1v_1).

The effect: in the microscope fAf_A is in the denominator of v1fA\dfrac{v_1}{f_A}, so MM decreases. In the telescope fAf_A is in the numerator, so mm increases.

Reading the options

The microscope decreases and the telescope increases. That is option (2).

(2): MM falls with v1fA\dfrac{v_1}{f_A}, m=fAfBm=\dfrac{f_A}{f_B} grows.

Why the other options fail

Both directions are swapped. In the microscope the objective works close up: a longer fAf_A makes v1fA−1\dfrac{v_1}{f_A}-1 smaller, so MM falls. In the telescope m=fAfBm=\dfrac{f_A}{f_B}, so a longer fAf_A makes mm grow.

The microscope does change. Its power is the product of two parts, and the objective part v1fA−1\dfrac{v_1}{f_A}-1 contains fAf_A. A longer fAf_A makes that part, and so MM, smaller.

A longer focal length helps only the telescope, m=fAfBm=\dfrac{f_A}{f_B}. The microscope objective must have a very short focal length: a longer fAf_A makes v1fA−1\dfrac{v_1}{f_A}-1 smaller, so MM falls.

The microscope part is right, but the telescope gets stronger. Its power is m=fAfBm=\dfrac{f_A}{f_B}, so a longer fAf_A with the same eyepiece makes mm larger.

Checks

The same in both: the eyepieces and the near point DD. Changed: only fAf_A. In one formula it divides, in the other it multiplies, so the two powers move in opposite directions.

With numbers: microscope with v1=16 cmv_1=16\ \text{cm}, fB=5 cmf_B=5\ \text{cm}, D=25 cmD=25\ \text{cm}:

fA=2 cmf_A=2\ \text{cm}: M=6×(8−1)=42M=6\times(8-1)=42

fA=4 cmf_A=4\ \text{cm}: M=6×(4−1)=18M=6\times(4-1)=18

Telescope with fB=5 cmf_B=5\ \text{cm}:

fA=100 cmf_A=100\ \text{cm}: m=20m=20

fA=200 cmf_A=200\ \text{cm}: m=40m=40

fA/fBfA/fB

Conclusion

M′<M, m′>mM'<M,\ m'>m

A longer fAf_A: MM decreases, m=fAfBm=\dfrac{f_A}{f_B} increases. The answer is (2).

Microscope: short objective, high power. Telescope: long objective, high power, m=fAfBm=\dfrac{f_A}{f_B}.

Exam tip

தமிழ் · සිංහල