2026 A/L Physics Past Paper · Question 31 (English Medium)

Cooling just after the heater is switched off

A calorimeter of heat capacity 50 J K−150\ \text{J K}^{-1} contains a liquid of mass 0.25 kg0.25\ \text{kg}. A 10 W10\ \text{W} immersion heater is placed in the liquid. The immersion heater is switched on and after some time the temperature of the liquid reaches a steady value. The heater is now switched off and it is observed that the initial rate of fall of temperature of the liquid is 1.0×10−2 K s−11.0\times10^{-2}\ \text{K s}^{-1}. What is the specific heat capacity of the liquid?

  1. (1) 3000 J kg−1K−13000\ \text{J kg}^{-1}\text{K}^{-1}
  2. (2) 3500 J kg−1K−13500\ \text{J kg}^{-1}\text{K}^{-1}
  3. (3) 3800 J kg−1K−13800\ \text{J kg}^{-1}\text{K}^{-1}
  4. (4) 4000 J kg−1K−14000\ \text{J kg}^{-1}\text{K}^{-1}
  5. (5) 4500 J kg−1K−14500\ \text{J kg}^{-1}\text{K}^{-1}
Answer and explanation

Answer: (3) 3800 J kg−1K−13800\ \text{J kg}^{-1}\text{K}^{-1}

Given information

This question is about a liquid that is kept warm by a heater and then left to cool.

While the heater is on, the liquid warms up until its temperature stops rising. From then on, every joule the heater gives is lost to the room.

What we must find: the specific heat capacity cc of the liquid.

How we find it: the heater power tells us how fast heat is lost at that temperature. Just after switching off, heat is still lost at that rate, and that loss makes the temperature fall at 0.01 K0.01\ \text{K} each second.

Heat capacity of the calorimeter: C=50 J K−1C=50\ \text{J K}^{-1}

Mass of the liquid: m=0.25 kgm=0.25\ \text{kg}

Power of the heater: P=10 WP=10\ \text{W}

Initial rate of fall of temperature: 1.0×10−2 K s−11.0\times10^{-2}\ \text{K s}^{-1}

What the question asks

What each letter means:

CC (J K−1\text{J K}^{-1}): the heat capacity of the calorimeter.

mm (kg\text{kg}): the mass of the liquid. cc (J kg−1K−1\text{J kg}^{-1}\text{K}^{-1}): its specific heat capacity.

PP (W\text{W}): the power of the heater, joules each second.

ΔθΔt\dfrac{\Delta\theta}{\Delta t} (K s−1\text{K s}^{-1}): how fast the temperature falls.

Plan: rate of loss of heat =P=P, then rate of loss =(C+mc)ΔθΔt=(C+mc)\dfrac{\Delta\theta}{\Delta t}, then solve for cc.

Relevant theory

The rate of loss of heat of a body, when it is cooling under conditions of forced convection, is directly propertional to the difference in temperature between the body and its surroundings.

Following equation can be used to calculate the amount of heat transferred from or to a body.

What is happening: the rate of loss of heat depends on how much hotter the liquid is than the room. At the steady temperature the heater gives 10 J10\ \text{J} each second and the liquid loses 10 J10\ \text{J} each second, so nothing changes.

Switch off the heater. At that moment the temperature is still the same, so the loss is still 10 J10\ \text{J} each second. Now nothing replaces it, and the liquid and calorimeter cool together:

Q=(C+mc)ΔθQ=(C+mc)\Delta\theta

For example, a pot of milk tea kept warm on a tiny stove flame at a tea shop.

After a while the tea stops getting hotter: the flame now gives exactly what the pot loses to the air. The moment the flame is turned off, the pot is still just as hot, so it loses heat just as fast, and it starts to cool straight away.

A big pot of tea cools slowly, a small cup cools fast, because more tea needs more heat to lose each degree.

Required equations

ΔQΔt=P\dfrac{\Delta Q}{\Delta t}=P

P=10 WP=10\ \text{W}

ΔQΔt=(C+mc)ΔθΔt\dfrac{\Delta Q}{\Delta t}=(C+mc)\dfrac{\Delta\theta}{\Delta t}

Applying it to this question

(50+0.25c)×0.01=10(50+0.25c)\times0.01=10

10001000

50+0.25c=100.0150+0.25c=\dfrac{10}{0.01}

950950

0.25c=1000−500.25c=1000-50

38003800

c=9500.25c=\dfrac{950}{0.25}

Reasoning and calculation

c=3800 J kg−1K−1c=3800\ \text{J kg}^{-1}\text{K}^{-1}. This is option (3).

With c=3000c=3000: (50+0.25×3000)×0.01=8 W(50+0.25\times3000)\times0.01=8\ \text{W}. But just after switching off, the loss must still be 10 W10\ \text{W}.

With c=3500c=3500: (50+0.25×3500)×0.01=9.25 W(50+0.25\times3500)\times0.01=9.25\ \text{W}, not 10 W10\ \text{W}.

This forgets the calorimeter. 0.25×c×0.01=100.25\times c\times0.01=10 gives 40004000, but the calorimeter cools too and gives out 50×0.01=0.5 W50\times0.01=0.5\ \text{W} of the 10 W10\ \text{W}.

With c=4500c=4500: (50+0.25×4500)×0.01=11.75 W(50+0.25\times4500)\times0.01=11.75\ \text{W}. That is more than the 10 W10\ \text{W} the heater was giving.

Checks

(50+0.25∗c)∗0.01(50 + 0.25 * c) * 0.01

Units: (C+mc)(C+mc) is in J K−1\text{J K}^{-1}, and times K s−1\text{K s}^{-1} gives J s−1=W\text{J s}^{-1}=\text{W}, a power, the same as the heater.

Does it make sense? The liquid gives out 0.25×3800×0.01=9.5 W0.25\times3800\times0.01=9.5\ \text{W} and the calorimeter 50×0.01=0.5 W50\times0.01=0.5\ \text{W}. Together:

9.5+0.5=10 W9.5+0.5=10\ \text{W}

This is exactly what the heater was giving.

Conclusion

c=3800 J kg−1K−1c=3800\ \text{J kg}^{-1}\text{K}^{-1}

At the steady temperature the loss is 10 W10\ \text{W}. Just after switching off, (C+mc)×0.01=10(C+mc)\times0.01=10, so c=3800 J kg−1K−1c=3800\ \text{J kg}^{-1}\text{K}^{-1}. The answer is (3).

A steady temperature means power in == rate of loss. Just after switching off, that same rate cools the liquid and its container together.

Exam tip

தமிழ் · සිංහල